7. Use UL listed wire connectors and connect the gray wires (G)
together.
8. Connect the green (or yellow/green) ground wire to the
green/yellow ground wire (H) in the terminal box using UL
listed wire connectors.
9. Reinstall the in-line blower terminal box cover and screw.
10. Reinstall the front cover of the in-line blower housing and
secure it with 10 mounting screws.
Electrical Connection Inside Downdraft Vent Between In-
line Blower System and Downdraft Vent
NOTE: Discard the 6-wire connector assembly supplied with
the in-line blower motor system.
1. With the downdraft vent mounted, locate the bottom wiring
cable (5 wires) inside the downdraft vent terminal box.
2. Connect the wires from the bottom wiring cable (5 wires)
inside the downdraft vent terminal box to the wires from the
in-line blower wiring conduit inside the downdraft vent
terminal box.
3. Connect the same color wires to each other (black to black,
white to white, etc.) using UL listed wire connectors.
NOTE: Connect the green (or green/yellow) ground wire from
the wiring conduit to the green (or bare) ground wire from the
home power supply using UL listed wire connectors (see the
“Make Electrical Power Supply Connections to Downdraft
Vent” section).
4. Go to “Make Electrical Power Supply Connection to
Downdraft Vent” section.
Make Electrical Power Supply Connection to
Downdraft Vent
1. Disconnect power.
2. Locate the downdraft vent terminal box.
3. Use UL listed wire connectors and connect black wires (D)
together.
A. UL listed or CSA approved
¹⁄₂
" (1.3 cm) wiring conduit
B. UL listed wire connectors
C. Black wires
D. White wires
E. Red wires
F. Blue wires
G. Gray wires
H. Green (or green/yellow)
wire
I. Bottom wiring cable
(5 wires)
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
B
C
D
E
F
G
H
I
A. Terminal box
A. Green or green and yellow
ground wires
B. White wires
C. UL listed wire connectors
D. Black wires
E. UL listed or CSA approved
conduit connector
F. Downdraft vent wiring
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
A
B
C
D
E
F