KitchenAid KHMD4 60510 Mode d'emploi Page 12

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 11
The minimum flow level is regulated using the tap at the lowest posi-
tion (small flame) .
There is no need to regulate the primary air in the burners.
To ensure the minimum level is properly regulated, remove the con-
trol knob and adjust the screws on the tap as follows:
1. Tighten to decrease the height of the flame 1 (-)
2. Loosen to increase the height of the flame (+);
3. With the burners on, turn the control knobs from the
maximum to the minimum position to check the stability
of the flame.
12
To replace the injectors in the special burner:
1. Remove the burner ring (A).
2. Unscrew the injector (B) using a 7 mm hex key.
3. Replace the injectors.
4. Refit the burner ring.
Note: Make sure that:
1. The burner ring (A) is seated correctly on the burner following
replacement.
A
B
Regulating the minimum flow level of the gas taps
Replacing the injectors in the wok burner
Vue de la page 11
1 2 ... 7 8 9 10 11 12 13 14 15 16

Commentaires sur ces manuels

Pas de commentaire